182 research outputs found

    Generative adversarial network-created brain SPECTs of cerebral ischemia are indistinguishable to scans from real patients

    Get PDF
    Deep convolutional generative adversarial networks (GAN) allow for creating images from existing databases. We applied a modified light-weight GAN (FastGAN) algorithm to cerebral blood flow SPECTs and aimed to evaluate whether this technology can generate created images close to real patients. Investigating three anatomical levels (cerebellum, CER; basal ganglia, BG; cortex, COR), 551 normal (248 CER, 174 BG, 129 COR) and 387 pathological brain SPECTs using N-isopropyl p-I-123-iodoamphetamine (I-123-IMP) were included. For the latter scans, cerebral ischemic disease comprised 291 uni- (66 CER, 116 BG, 109 COR) and 96 bilateral defect patterns (44 BG, 52 COR). Our model was trained using a three-compartment anatomical input (dataset 'A'; including CER, BG, and COR), while for dataset 'B', only one anatomical region (COR) was included. Quantitative analyses provided mean counts (MC) and left/right (LR) hemisphere ratios, which were then compared to quantification from real images. For MC, 'B' was significantly different for normal and bilateral defect patterns (P = 0.08) reached significance relative to images of real patients. With a minimum of only three anatomical compartments serving as stimuli, created cerebral SPECTs are indistinguishable to images from real patients. The applied FastGAN algorithm may allow to provide sufficient scan numbers in various clinical scenarios, e.g., for "data-hungry" deep learning technologies or in the context of orphan diseases

    Disconnectivity between Dorsal Raphe Nucleus and Posterior Cingulate Cortex in Later Life Depression

    Get PDF
    The dorsal raphe nucleus (DRN) has been repeatedly implicated as having a significant relationship with depression, along with its serotoninergic innervation. However, functional connectivity of the DRN in depression is not well understood. The current study aimed to isolate functional connectivity of the DRN distinct in later life depression (LLD) compared to a healthy age-matched population. Resting state functional magnetic resonance imaging (rsfMRI) data from 95 participants (33 LLD and 62 healthy) were collected to examine functional connectivity from the DRN to the whole brain in voxel-wise fashion. The posterior cingulate cortex (PCC) bilaterally showed significantly smaller connectivity in the LLD group than the control group. The DRN to PCC connectivity did not show any association with the depressive status. The findings implicate that the LLD involves disruption of serotoninergic input to the PCC, which has been suggested to be a part of the reduced default mode network in depression

    Surface Shape Measurement by Grating Projection Method in Aerospace Structures

    Get PDF
    To improve the accuracy of the grating projection method of a surface shape measurement method without contact, several attempts are proposed and verified. A whole-space tabulation method (WSTM) is demonstrated to measure a translucent glittering metallic mesh of a parabolic antenna for a radio astronomy satellite. A transparence method of the grating projection method is proposed to measure a glossy polymer film often used in space structures. An extrapolation method is proposed to measure a larger object than the reference planes. A pre-calibration can be used to adjust the measured value to the real values. The extrapolation method and the pre-calibration are demonstrated to measure a displacement of a wing of a developing airplane under loading.ē‰¹é›† : čˆŖē©ŗå®‡å®™ę©Ÿć‚·ć‚¹ćƒ†ćƒ ē ”ē©¶ć‚»ćƒ³ć‚æćƒ¼ć«ćŠć‘ć‚‹é–‹ē™ŗē ”ē©¶2 : 5. ć‚Ŗć‚ŖćƒÆć‚·IIé£›č”Œć«ć‚€ć‘ć¦äø¦ć³ć«é–¢é€£ęŠ€č”“恮ē ”ē©¶é–‹ē™ŗļ¼ˆé–¢é€£ē ”ē©¶é–‹ē™ŗ分野

    Sialyl LewisX mimic-decorated liposomes for anti-angiogenic everolimus delivery to E-selectin expressing endothelial cells

    Get PDF
    In this study, we developed novel E-selectin-targeting liposomes, i.e., 3ā€²-(1-carboxy)ethyl sialyl LewisX (3ā€²-CE sLeX) mimic liposomes, for targeted delivery of everolimus (EVE) in anti-angiogenic therapy. We investigated the uptake and efficacy of these E-selectin targeting liposomes in inflammatory cytokine-treated human umbilical vein endothelial cells (HUVECs). The uptake of EVE in 3ā€²-CE sLeX mimic liposomes increased steadily and almost caught up with the uptake of plain EVE at 3 h, which was higher than that in PEGylated liposomes (PEG-liposomes). Inhibition of uptake by anti-E-selectin antibody suggested involvement of E-selectin-mediated endocytotic processes. Migration in cells treated with EVE/3ā€²-CE sLeX mimic liposomes was suppressed by more than half when compared to the control. This treatment was also seen to significantly inhibit the formation of capillary tubes and networks. In addition, Thr389 phosphorylation of pS6 kinase, as a marker of mTOR activity, was remarkably suppressed to less than endogenous levels by EVE/3ā€²-CE sLeX mimic liposomes. In conclusion, the present study demonstrated that EVE/3ā€²-CE sLeX mimic liposomes were intracellularly taken up by E-selectin and prompted anti-angiogenic effects of EVE involved in the mTOR signaling pathway. However, moderate retention of EVE in the liposomes might limit the targeting ability of 3ā€²-CE sLeX mimic liposomes

    Performance evaluation of a preclinical SPECT scanner with a collimator designed for medium-sized animals

    Get PDF
    BACKGROUND: Equipped with two stationary detectors, a large bore collimator for medium-sized animals has been recently introduced for dedicated preclinical single-photon emission computed tomography (SPECT) imaging. We aimed to evaluate the basic performance of the system using phantoms and healthy rabbits. METHODS: A general-purpose medium-sized animal (GP-MSA) collimator with 135ā€‰mm bore diameter and thirty-three holes of 2.5ā€‰mm diameter was installed on an ultrahigh-resolution scanner equipped with two large stationary detectors (U-SPECT5-E/CT). The sensitivity and uniformity were investigated using a point source and a cylinder phantom containing (99m)Tc-pertechnetate, respectively. Uniformity (in %) was derived using volumes of interest (VOIs) on images of the cylinder phantom and calculated as [(maximumā€‰count āˆ’ minimumā€‰count)/(maximumā€‰count + minimumā€‰count) Ɨ 100], with lower values of % indicating superior performance. The spatial resolution and contrast-to-noise ratios (CNRs) were evaluated with images of a hot-rod Derenzo phantom using different activity concentrations. Feasibility of in vivo SPECT imaging was finally confirmed by rabbit imaging with the most commonly used clinical myocardial perfusion SPECT agent [(99m)Tc]Tc-sestamibi (dynamic acquisition with a scan time of 5ā€‰min). RESULTS: In the performance evaluation, a sensitivity of 790ā€‰cps/MBq, a spatial resolution with the hot-rod phantom of 2.5ā€‰mm, and a uniformity of 39.2% were achieved. The CNRs of the rod size 2.5ā€‰mm were 1.37, 1.24, 1.20, and 0.85 for activity concentration of 29.2, 1.0, 0.5, and 0.1ā€‰MBq/mL, respectively. Dynamic SPECT imaging in rabbits allowed to visualize most of the thorax and to generate time-activity curves of the left myocardial wall and ventricular cavity. CONCLUSION: Preclinical U-SPECT5-E/CT equipped with a large bore collimator demonstrated adequate sensitivity and resolution for in vivo rabbit imaging. Along with its unique features of SPECT molecular functional imaging is a superior collimator technology that is applicable to medium-sized animal models and thus may promote translational research for diagnostic purposes and development of novel therapeutics

    [18F]FDG-labelled stem cell PET imaging in different route of administrations and multiple animal species

    Get PDF
    Stem cell therapy holds great promise for tissue regeneration and cancer treatment, although its efficacy is still inconclusive and requires further understanding and optimization of the procedures. Non-invasive cell tracking can provide an important opportunity to monitor in vivo cell distribution in living subjects. Here, using a combination of positron emission tomography (PET) and in vitro 2-deoxy-2-[18F]fluoro-D-glucose ([18F]FDG) direct cell labelling, the feasibility of engrafted stem cell monitoring was tested in multiple animal species. Human mesenchymal stem cells (MSCs) were incubated with phosphate-buffered saline containing [18F]FDG for in vitro cell radiolabelling. The pre-labelled MSCs were administrated via peripheral vein in a mouse (n=1), rats (n=4), rabbits (n=4) and non-human primates (n=3), via carotid artery in rats (n=4) and non-human primates (n=3), and via intra-myocardial injection in rats (n=5). PET imaging was started 10 min after cell administration using a dedicated small animal PET system for a mouse and rats. A clinical PET system was used for the imaging of rabbits and non-human primates. After MSC administration via peripheral vein, PET imaging revealed intense radiotracer signal from the lung in all tested animal species including mouse, rat, rabbit, and non-human primate, suggesting administrated MSCs were trapped in the lung tissue. Furthermore, the distribution of the PET signal significantly differed based on the route of cell administration. Administration via carotid artery showed the highest activity in the head, and intra-myocardial injection increased signal from the heart. In vitro [18F]FDG MSC pre-labelling for PET imaging is feasible and allows non-invasive visualization of initial cell distribution after different routes of cell administration in multiple animal models. Those results highlight the potential use of that imaging approach for the understanding and optimization of stem cell therapy in translational research

    Initial Evaluation of AF78: a Rationally Designed Fluorine-18-Labelled PET Radiotracer Targeting Norepinephrine Transporter

    Get PDF
    Purpose Taking full advantage of positron emission tomography (PET) technology, fluorine-18-labelled radiotracers targeting norepinephrine transporter (NET) have potential applications in the diagnosis and assessment of cardiac sympathetic nerve conditions as well as the delineation of neuroendocrine tumours. However, to date, none have been used clinically. Drawbacks of currently reported radiotracers include suboptimal kinetics and challenging radiolabelling procedures. Procedures We developed a novel fluorine-18-labelled radiotracer targeting NET, AF78, with efficient one-step radiolabelling based on the phenethylguanidine structure. Radiosynthesis of AF78 was undertaken, followed by validation in cell uptake studies, autoradiography, and in vivo imaging in rats. Results [18F]AF78 was successfully synthesized with 27.9ā€‰Ā±ā€‰3.1 % radiochemical yield, >ā€‰97 % radiochemical purity and >ā€‰53.8 GBq/mmol molar activity. Cell uptake studies demonstrated essentially identical affinity for NET as norepinephrine and meta-iodobenzylgaunidine. Both ex vivo autoradiography and in vivo imaging in rats showed homogeneous and specific cardiac uptake. Conclusions The new PET radiotracer [18F]AF78 demonstrated high affinity for NET and favourable biodistribution in rats. A structure-activity relationship between radiotracer structures and affinity for NET was revealed, which may serve as the basis for the further design of NET targeting radiotracers with favourable features

    Molecular imaging-derived biomarker of cardiac nerve integrity ā€” introducing high NET affinity PET probe 18F-AF78

    Get PDF
    Background: Radiolabeled agents that are substrates for the norepinephrine transporter (NET) can be used to quantify cardiac sympathetic nervous conditions and have been demonstrated to identify high-risk congestive heart failure (HF) patients prone to arrhythmic events. We aimed to fully characterize the kinetic profile of the novel (18)F-labeled NET probe AF78 for PET imaging of the cardiac sympathetic nervous system (SNS) among various species. Methods: (18)F-AF78 was compared to norepinephrine (NE) and established SNS radiotracers by employing in vitro cell assays, followed by an in vivo PET imaging approach with healthy rats, rabbits and nonhuman primates (NHPs). Additionally, chase protocols were performed in NHPs with NET inhibitor desipramine (DMI) and the NE releasing stimulator tyramine (TYR) to investigate retention kinetics in cardiac SNS. Results: Relative to other SNS radiotracers, (18)F-AF78 showed higher transport affinity via NET in a cell-based competitive uptake assay (IC(50) 0.42 Ā± 0.14 ĀµM), almost identical to that of NE (IC(50), 0.50 Ā± 0.16 ĀµM, n.s.). In rabbits and NHPs, initial cardiac uptake was significantly reduced by NET inhibition. Furthermore, cardiac tracer retention was not affected by a DMI chase protocol but was markedly reduced by intermittent TYR chase, thereby suggesting that (18)F-AF78 is stored and can be released via the synaptic vesicular turnover process. Computational modeling hypothesized the formation of a T-shaped Ļ€-Ļ€ stacking at the binding site, suggesting a rationale for the high affinity of (18)F-AF78. Conclusion: (18)F-AF78 demonstrated high in vitro NET affinity and advantageous in vivo radiotracer kinetics across various species, indicating that (18)F-AF78 is an SNS imaging agent with strong potential to guide specific interventions in cardiovascular medicine

    In vivo functional assessment of Sodium-Glucose Cotransporters (SGLTs) using [18F]Me4FDG PET in rats

    Get PDF
    BACKGROUND: Mediating glucose absorption in the small intestine and renal clearance, sodium glucose cotransporters (SGLTs) have emerged as an attractive therapeutic target in diabetic patients. A substantial fraction of patients, however, only achieve inadequate glycemic control. Thus, we aimed to assess the potential of the SGLT-targeting PET radiotracer alpha-methyl-4-deoxy-4-[(18)F]fluoro-D-glucopyranoside ([(18)F]Me4FDG) as a noninvasive intestinal and renal biomarker of SGLT-mediated glucose transport. METHODS: We investigated healthy rats using a dedicated small animal PET system. Dynamic imaging was conducted after administration of the reference radiotracer 2-deoxy-2-[(18)F]fluoro-D-glucose ([(18)F]FDG), or the SGLT-targeting agent, [(18)F]Me4FDG either directly into the digestive tract (for assessing intestinal absorption) or via the tail vein (for evaluating kidney excretion). To confirm the specificity of [(18)F]Me4FDG and responsiveness to treatment, a subset of animals was also pretreated with the SGLT inhibitor phlorizin. In this regard, an intraintestinal route of administration was used to assess tracer absorption in the digestive tract, while for renal assessment, phlorizin was injected intravenously (IV). RESULTS: Serving as reference, intestinal administration of [(18)F]FDG led to slow absorption with retention of 89.2 Ā± 3.5% of administered radioactivity at 15ā€‰min. [(18)F]Me4FDG, however, was rapidly absorbed into the blood and cleared from the intestine within 15ā€‰min, leading to markedly lower tracer retention of 18.5 Ā± 1.2% (P < 0.0001). Intraintestinal phlorizin led to marked increase of [(18)F]Me4FDG uptake (15ā€‰min, 99.9 Ā± 4.7%; P < 0.0001 vs. untreated controls), supporting the notion that this PET agent can measure adequate SGLT inhibition in the digestive tract. In the kidneys, radiotracer was also sensitive to SGLT inhibition. After IV injection, [(18)F]Me4FDG reabsorption in the renal cortex was significantly suppressed by phlorizin when compared to untreated animals (%ID/g at 60ā€‰min, 0.42 Ā± 0.10 vs. untreated controls, 1.20 Ā± 0.03; P < 0.0001). CONCLUSION: As a noninvasive read-out of the concurrent SGLT expression in both the digestive tract and the renal cortex, [(18)F]Me4FDG PET may serve as a surrogate marker for treatment response to SGLT inhibition. As such, [(18)F]Me4FDG may enable improvement in glycemic control in diabetes by PET-based monitoring strategies

    Capabilities of multi-pinhole SPECT with two stationary detectors for in vivo rat imaging

    Get PDF
    We aimed to investigate the image quality of the U-SPECT5/CT E-Class a micro single-photon emission computed tomography (SPECT) system with two large stationary detectors for visualization of rat hearts and bones using clinically available Tc-99m-labelled tracers. Sensitivity, spatial resolution, uniformity and contrast-to-noise ratio (CNR) of the small-animal SPECT scanner were investigated in phantom studies using an ultra-high-resolution rat and mouse multi-pinhole collimator (UHR-RM). Point source, hot-rod, and uniform phantoms with Tc-99m-solution were scanned for high-count performance assessment and count levels equal to animal scans, respectively. Reconstruction was performed using the similarity-regulated ordered-subsets expectation maximization (SROSEM) algorithm with Gaussian smoothing. Rats were injected with similar to 100 MBq [Tc-99m]Tc-MIBI or similar to 150 MBq [Tc-99m]Tc-HMDP and received multi-frame micro-SPECT imaging after tracer distribution. Animal scans were reconstructed for three different acquisition times and post-processed with different sized Gaussian filters. Following reconstruction, CNR was calculated and image quality evaluated by three independent readers on a five-point scale from 1="very poor" to 5="very good". Point source sensitivity was 567 cps/MBq and radioactive rods as small as 1.2 mm were resolved with the UHR-RM collimator. Collimator-dependent uniformity was 55.5%. Phantom CNR improved with increasing rod size, filter size and activity concentration. Left ventricle and bone structures were successfully visualized in rat experiments. Image quality was strongly affected by the extent of post-filtering, whereas scan time did not have substantial influence on visual assessment. Good image quality was achieved for resolution range greater than 1.8 mm in bone and 2.8 mm in heart. The recently introduced small animal SPECT system with two stationary detectors and UHR-RM collimator is capable to provide excellent image quality in heart and bone scans in a rat using standardized reconstruction parameters and appropriate post-filtering. However, there are still challenges in achieving maximum system resolution in the sub-millimeter range with in vivo settings under limited injection dose and acquisition time
    • ā€¦
    corecore